To enhance security, Multi-Factor Authentication (MFA) is mandatory for all HL7 users. More information

Section 1c: FHIR®
Section 3: Implementation Guides

HL7 FHIR® R4 Implementation Guide: Personal Health Device (PHD), Edition 2

DESCRIPTION

This Implementation Guide (IG) defines the use of FHIR resources to convey measurements and supporting data from communicating Personal Health Devices (PHDs) to receiving systems for electronic medical records, clinical decision support, and medical data archiving for aggregate quality measurement and research purposes.

See the specification at http://hl7.org/fhir/uv/phd/STU2

ALTERNATIVE NAMES

HL7 FHIR® R4 Implementation Guide: Personal Health Device (PHD), Edition 2 may also go by the following names or acronyms:

"FHIR IG: PCD, R1",,DoF-PHD IG

BENEFITS

  • Provides a representation of measurements and information generated by personal health medical devices in FHIR.

IMPLEMENTATIONS/CASE STUDIES

This FHIR Implementation Guide is being used by

  • IHE Profiles developed by IHE Devices working group, 
  • device vendors and Health IT solutions in the field in remote patient monitoring scenarios

DEVELOPMENT BACKGROUND

The 2.0 version of the PHD IG is a major update revamped to take advantage of the latest version of the "IEEE 11073-10206 PHD - Abstract Content Model” standard. The IG includes updated and new structure definitions and profiles that now follow HL7 FHIR best practices and revise the mappings of IEEE 11073 PHD data to FHIR resources that were present in the 1.0 version. It also includes resolutions of all comments / JIRA tickets from earlier ballot rounds.

The one Substantive change (https://jira.hl7.org/browse/FHIR-52861) that was implemented after the ballot, was vetted via a two week review period that ended on November 10th. Comments received during the review period did not relate to that Substantive change and are deferred to the next revision.

RELATED DOCUMENTS

HL7 FHIR® R4 Implementation Guide: Personal Health Device (PHD), Edition 2

STU DOCUMENTS

HL7 FHIR® Implementation Guide: Personal Health Device (PHD), Edition 2 See the standard at '>http://hl7.org/fhir/uv/phd/STU2'>. (Submit Feedback on STU)
HL7 FHIR® Implementation Guide: Personal Health Device (PHD), Release 1.1 See the standard at http://hl7.org/fhir/us/phd/STU1.1. (Submit Feedback on STU)
HL7 FHIR® Implementation Guide: Personal Health Device (PHD), Release 1 See the standard at http://hl7.org/fhir/uv/phd/STU1. Expiration May 2024

TOPIC

  • Healthcare Devices

BALLOT TYPE

  • STU

STATUS DATE

2026-03-31

RESPONSIBLE WORK GROUP

Devices

PRODUCT TYPE

  • Implementation Guide

STAKEHOLDERS

  • EHR, PHR Vendors
  • Equipment Vendors
  • Health Care IT Vendors
  • Healthcare Institutions
  • Regulatory Agency
  • Standards Development Organizations (SDOs)

FAMILY

  • FHIR

CURRENT STATE

  • Active

REALM

  • Universal